1. Academic Validation
  2. Determination of amino acid neurotransmitters in rat hippocampi by HPLC-UV using NBD-F as a derivative

Determination of amino acid neurotransmitters in rat hippocampi by HPLC-UV using NBD-F as a derivative

  • Biomed Chromatogr. 2014 Apr;28(4):459-62. doi: 10.1002/bmc.3062.
Xiaomeng Wu 1 Rui Wang Qingqing Jiang Shue Wang Yao Yao Lihua Shao
Affiliations

Affiliation

  • 1 Department of Sanitary Inspection, School of Public Health, Shandong University, Jinan, China.
Abstract

A simple, rapid and accurate high-performance liquid chromatography method with ultraviolet-visible detection was developed for the determination of five amino acid neurotransmitters - aspartate, glutamic acid, glycine, taurine and γ-aminobutyric acid - in rat hippocampi with pre-column derivatization with 4-fluoro-7-nitrobenzofurazan. Several conditions which influenced derivatization and separation, such as pH, temperature, acetonitrile percentage mobile phase and flow rate, were optimized to obtain a suitable protocol for Amino acids quantification in samples. The separation of the five neurotransmitter derivatives was performed on a C18 column using a mobile phase consisting of phosphate buffer (0.02 mol/L, pH 6.0)-acetonitrile (84:16, v/v) at a flow rate of 1.0 mL/min with the column temperature at 30°C. The detection wavelength was 472 nm. Without gradient elution, the five neurotransmitter derivatives were completely separated within 15 min. The linear relation was good in the range from 0.50 to 500 µmol/L, and the correlation coefficients were ≥0.999. Intra-day precision was between 1.8 and 3.2%, and inter-day precision was between 2.4 and 4.7%. The limits of detection (signal-to-noise ratio 3) were from 0.02 to 0.15 µmol/L. The established method was used to determine amino acid neurotransmitters in rat hippocampi with satisfactory recoveries varying from 94.9 to 105.2%.

Keywords

4-fluoro-7-nitrobenzofurazan (NBD-F); HPLC-UV; amino acid neurotransmitters; derivatization; hippocampi.

Figures
Products