1. Academic Validation
  2. Determination of PNU-248686A, a novel matrix metalloproteinase inhibitor, in human plasma by liquid chromatography-tandem mass spectrometry, following protein precipitation in the 96-well plate format

Determination of PNU-248686A, a novel matrix metalloproteinase inhibitor, in human plasma by liquid chromatography-tandem mass spectrometry, following protein precipitation in the 96-well plate format

  • J Chromatogr A. 2003 Feb 14;987(1-2):249-56. doi: 10.1016/s0021-9673(02)01907-6.
E Frigerio 1 V Cenacchi C A James
Affiliations

Affiliation

  • 1 Global Drug Metabolism, Pharmacia, Viale Pasteur 10, 20014 Nerviano, Milan, Italy. [email protected]
Abstract

A sensitive, specific and high-throughput analytical method for the quantitation of PNU-248686A (I), in human plasma has been developed. I, sodium (2R)-3-[[(4'-chloro(1,1'-biphenyl)-4-yl]sulfonyl]-2-hydroxy-2-[(phenylsulfanyl)methyl] propanoate, is an orally active matrix metalloproteinase (MMP) inhibitor developed for the treatment of solid tumors over-expressing MMPs. Concentrations of I, as free acid, were determined in human plasma by LC-MS-MS after plasma protein precipitation in the 96-well plate format. Aliquots of plasma (50 microl) were placed into the plates and 0.2 ml of methanol was added. The plates were shaken for 5 min and centrifuged at 1500 g for 10 min. Aliquots of 10 microl of the supernatants were then directly injected into the LC-MS-MS system. A Symmetry Shield C. column (50 x 2.1 mm, 3.5 microm) was used to perform the chromatographic analysis. The mobile phase was 5 mM ammonium formate buffer solution pH 5.0-acetonitrile (60:40. v/v) with a flow-rate of 0.3 ml/min. Retention time of I was about 1.2 min. Total cycle time was 2.5 min. MS detection used the Applied Biosystems-MDS Sciex API 3000 with TurbolonSpray interface and single reaction monitoring (461 --> 251 m/z transition) operated in negative ion mode. Calibration curves were constructed by plotting the area of the compound (y) against its concentration (x). A weighed linear regression (weighting factor 1/x(2)) was used to calculate I concentrations in quality control and unknown samples. The method was fully validated over the range of 5.0-5000 ng/ml. The suitability and robustness of the method for in vivo samples was confirmed by analysis of plasma samples from a pilot clinical study.

Figures
Products
  • Cat. No.
    Product Name
    Description
    Target
    Research Area
  • HY-19422
    MMP Inhibitor
    MMP