1. Academic Validation
  2. Development and validation of an LC-MS/MS method for the determination of a novel thienoquinolin urea transporter inhibitor PU-48 in rat plasma and its application to a pharmacokinetic study

Development and validation of an LC-MS/MS method for the determination of a novel thienoquinolin urea transporter inhibitor PU-48 in rat plasma and its application to a pharmacokinetic study

  • Biomed Chromatogr. 2018 Apr;32(4). doi: 10.1002/bmc.4157.
Zhi-Yuan Zhang 1 Xin Wang 1 Dan Liu 2 Hua Zhang 3 Qiang Zhang 3 Ying-Yuan Lu 1 Pu Li 1 Ya-Qing Lou 1 Bao-Xue Yang 1 Chuang Lu 4 Ya-Xin Lou 2 Guo-Liang Zhang 1
Affiliations

Affiliations

  • 1 Department of Pharmacology, School of Basic Medical Sciences, Peking University, Beijing, China.
  • 2 Proteomics Laboratory, Medical and Health Analysis Center, Peking University, Beijing, China.
  • 3 Department of Pharmaceutics, School of Pharmaceutical Sciences, Peking University, Beijing, China.
  • 4 Department of Drug Metabolism and Pharmacokinetics, Biogen, Cambridge, Massachusetts, USA.
Abstract

A specific, sensitive and stable high-performance liquid chromatographic-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantitative determination of methyl 3-amino-6-methoxythieno [2,3-b]quinoline-2-carboxylate (PU-48), a novel diuretic thienoquinolin Urea Transporter Inhibitor in rat plasma. In this method, the chromatographic separation of PU-48 was achieved with a reversed-phase C18 column (100 × 2.1 mm, 3 μm) at 35°C. The mobile phase consisted of acetonitrile and water with 0.05% formic acid added with a gradient elution at flow rate of 0.3 mL/min. Samples were detected with the triple-quadrupole tandem mass spectrometer with multiple reaction monitoring mode via electrospray ionization source in positive mode. The retention time were 6.2 min for PU-48 and 7.2 min for megestrol acetate (internal standard, IS). The monitored ion transitions were mass-to-charge ratio (m/z) 289.1 → 229.2 for PU-48 and m/z 385.3 → 267.1 for the internal standard. The calibration curve for PU-48 was linear over the concentration range of 0.1-1000 ng/mL (r2 > 0.99), and the lower limit of quantitation was 0.1 ng/mL. The precision, accuracy and stability of the method were validated adequately. The developed and validated method was successfully applied to the pharmacokinetic study of PU-48 in rats.

Keywords

liquid chromatography-tandem mass spectrometry (LC-MS/MS); methyl 3-amino-6-methoxythieno [2,3-b] quinolone-2-carboxylate (PU-48); pharmacokinetics; rat; thienoquinolin urea transporter inhibitor.

Figures
Products