1. Academic Validation
  2. A mechanically active nucleus pulposus-on-a-chip for studying mechanobiology and therapeutic strategies in intervertebral disc disease

A mechanically active nucleus pulposus-on-a-chip for studying mechanobiology and therapeutic strategies in intervertebral disc disease

  • Biofabrication. 2026 Feb 5;18(1). doi: 10.1088/1758-5090/ae3d85.
Olga Krupkova 1 2 Bianca Aterini 1 3 Nader Rahal 3 Elias Schulze 4 Salim Darwiche 5 Martin Ehrbar 6 7 Karoliina Pelttari 1 Ivan Martin 1 Stefan Schären 2 Arne Mehrkens 1 2 Andrea Barbero 1 Andrea Mainardi 1
Affiliations

Affiliations

  • 1 Department of Biomedicine, University Hospital Basel, University of Basel, Hebelstrasse 20, 4031 Basel, Switzerland.
  • 2 Spine Surgery, University Hospital Basel, Spitalstrasse 21, 4031 Basel, Switzerland.
  • 3 Department of Electronics, Information and Bioengineering, Politecnico di Milano, Via Golgi 39, 20133 Milan, Italy.
  • 4 Institut für Pathologie, University Hospital Basel, Schönbeinstrasse 40, 4031 Basel, Switzerland.
  • 5 Musculoskeletal Research Unit (MSRU), University of Zurich, Winterthurerstrasse 190, 8057 Zürich, Switzerland.
  • 6 Department of Obstetrics, University Hospital Zürich, Frauenklinikstrasse 10, 8091, Zürich, Switzerland.
  • 7 Zürich Centre for Integrative Human Physiology, Winterthurerstrasse 190, 8057 Zürich, Switzerland.
Abstract

Intervertebral disc (IVD) degeneration is the primary contributor to low back pain, the leading cause of disability worldwide. Although various triggers have been associated with IVD degeneration, its precise aetiology remains unclear. Consequently, current treatments fail to address the underlying degradative processes. Mechanical loading plays a critical role in IVD homeostasis, and aberrant mechanical stimulation has been identified as a key driver of extracellular matrix degradation in the proteoglycan-rich core of the IVD-the nucleus pulposus (NPs). Elucidating the molecular mechanisms of IVD mechanotransduction could therefore be pivotal in identifying effective drug targets. However, we are lacking easy-to-use, reliable models to study IVD's mechanobiological mechanisms in human cells. Here, we present the first mechanically active, microscale, human cell-based NP-on-a-Chip (NPoC) model that mimics the native NP microenvironment and enables controlled investigation of mechanically induced degenerative processes. Starting from primary human NP cells, we demonstrate that hypoxic culture (i.e. 2% O2) results in 3D constructs with gene expression levels of NP markers (ACAN, COL2A1, CDH2, OVOS2), and matrix composition (Collagen type II and glycosaminoglycans) comparable with the native NP tissue. NPoC constructs respond to cyclic compression in an intensity- and duration-dependent manner. Physiological compression (10%) enhances glycosaminoglycan deposition, whereas hyperphysiological compression (30%), especially if prolonged in time (16 h d-1), induces upregulation of inflammatory and catabolic markers (PTGS2, MMP13), matrix degradation, and increased apoptosis-thus recapitulating clinical hallmarks of NP degeneration. As a proof of concept for the platform's perspective utility in therapeutic screening, we demonstrate that inhibition of the mechanoresponsive channel TRPV4 with GSK205 restores baseline expression levels of mechanosensitive and catabolic genes. The new NPoC is thus suitable for studying NP mechanobiology and screening mechanotransduction-targeting drugs, and it may facilitate the future discovery of disease modifying therapies for discogenic low back pain.

Keywords

intervertebral disc degeneration; mechanobiology; mechanotransduction; nucleus pulposus; organ-on-chip.

Figures
Products