1. Academic Validation
  2. Development of an enantioselective assay for simultaneous separation of venlafaxine and O-desmethylvenlafaxine by micellar electrokinetic chromatography-tandem mass spectrometry: Application to the analysis of drug-drug interaction

Development of an enantioselective assay for simultaneous separation of venlafaxine and O-desmethylvenlafaxine by micellar electrokinetic chromatography-tandem mass spectrometry: Application to the analysis of drug-drug interaction

  • J Chromatogr A. 2015 Nov 13;1420:119-28. doi: 10.1016/j.chroma.2015.09.088.
Yijin Liu 1 Michael Jann 2 Chad Vandenberg 3 Chin B Eap 4 Shahab A Shamsi 5
Affiliations

Affiliations

  • 1 Center of Diagnostics and Therapeutics, Georgia State University, Atlanta, GA 30303, United States.
  • 2 Health Science Center, University of North Texas, Fort Worth, TX 76107, United States.
  • 3 Midwestern University, Institute for Healthcare Innovation, Glendale, AZ 85308, United States.
  • 4 Unit of Pharmacogenetics and Clinical Psychopharmacology, Department of Psychiatry, Lausanne University, Hospital of Cery, Prilly, Lausanne, Switzerland.
  • 5 Center of Diagnostics and Therapeutics, Georgia State University, Atlanta, GA 30303, United States. Electronic address: [email protected].
Abstract

To-date, there has been no effective chiral capillary electrophoresis-mass spectrometry (CE-MS) method reported for the simultaneous enantioseparation of the antidepressant drug, venlafaxine (VX) and its structurally-similar major metabolite, O-desmethylvenlafaxine (O-DVX). This is mainly due to the difficulty of identifying MS compatible chiral selector, which could provide both high enantioselectivity and sensitive MS detection. In this work, poly-sodium N-undecenoyl-L,L-leucylalaninate (poly-L,L-SULA) was employed as a chiral selector after screening several dipeptide polymeric chiral surfactants. Baseline separation of both O-DVX and VX enantiomers was achieved in 15 min after optimizing the buffer pH, poly-L,L-SULA concentration, nebulizer pressure and separation voltage. Calibration curves in spiked plasma (recoveries higher than 80%) were linear over the concentration range 150-5000 ng/mL for both VX and O-DVX. The limit of detection (LOD) was found to be as low as 30 ng/mL and 21 ng/mL for O-DVX and VX, respectively. This method was successfully applied to measure the plasma concentrations of human volunteers receiving VX or O-DVX orally when co-administered without and with indinivar therapy. The results suggest that micellar electrokinetic chromatography electrospray ionization-tandem mass spectrometry (MEKC-ESI-MS/MS) is an effective low cost alternative technique for the pharmacokinetics and pharmacodynamics studies of both O-DVX and VX enantiomers. The technique has potential to identify drug-drug interaction involving VX and O-DVX enantiomers while administering indinivar therapy.

Keywords

Enantioseparation; MKEC-ESI-MS/MS; Poly-L,L-SULA; Venlafaxine/O-desmethylvenlafaxine.

Figures