1. Academic Validation
  2. Quantification of 2-NBDG, a probe for glucose uptake, in GLUT1 overexpression in HEK293T cells by LC-MS/MS

Quantification of 2-NBDG, a probe for glucose uptake, in GLUT1 overexpression in HEK293T cells by LC-MS/MS

  • Anal Biochem. 2021 Oct 15;631:114357. doi: 10.1016/j.ab.2021.114357.
Yanhong Sun 1 Minwan Hu 1 Fenghe Wang 1 Huixin Tan 1 Jiahuan Hu 1 Xinbo Wang 1 Baolian Wang 1 Jinping Hu 2 Yan Li 1
Affiliations

Affiliations

  • 1 State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Department of Drug Metabolism, Beijing Key Laboratory of Non-Clinical Drug Metabolism and PK/PD Study, Beijing Key Laboratory of Active Substances Discovery and Drug Ability Evaluation, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China.
  • 2 State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Department of Drug Metabolism, Beijing Key Laboratory of Non-Clinical Drug Metabolism and PK/PD Study, Beijing Key Laboratory of Active Substances Discovery and Drug Ability Evaluation, Institute of Materia Medica, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100050, China. Electronic address: [email protected].
Abstract

The growth and proliferation of most Cancer cells involve the excessive uptake of glucose mediated by glucose transporters. An effective strategy for Cancer therapy has been to inhibit the GLUTs that are usually overexpressed in a variety of tumor cells. 2-NBDG is a GLUT1 substrate that can be used as a probe for GLUT1 inhibitors. An accurate and simple assay for 2-NBDG in a HEK293T cell model overexpressing GLUT1 was developed using liquid chromatography-tandem mass spectrometry. Chromatographic separation was achieved using a Xbridge® Amide column (3.5 μm, 2.1 mm × 150 mm, Waters) with acetonitrile-water containing 2 μM ammonium acetate (80:20, v/v) at a flow rate of 0.25 mL/min. Mass detection was conducted in the parallel reaction monitoring (PRM) mode. The calibration curve for 2-NBDG showed good linearity in the concentration range of 5-500 ng/mL with satisfactory precision, a relative standard deviation ranging from 2.92 to 9.59% and accuracy with a relative error ranging from -13.14 to 7.34%. This method was successfully applied to quantify the uptake of GLUT1-mediated 2-NBDG, and the results clearly indicated inhibition of GLUT1 by WZB117 and quercetin (two potent glucose transporter inhibitors) in the GLUT1-HEK293T cell model. This study provides a convenient and accurate method for high-throughput screening of selective and promising GLUT1 inhibitors.

Keywords

2-NBDG; GLUT1; High-throughput; Inhibition of glucose transport; LC–MS/MS; Natural products.

Figures
Products