1. Academic Validation
  2. Determination of two progestin metabolites (17α-hydroxypregnanolone and pregnanediol) and different classes of steroids (androgens, estrogens, corticosteroids, progestins) in rivers and wastewaters by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)

Determination of two progestin metabolites (17α-hydroxypregnanolone and pregnanediol) and different classes of steroids (androgens, estrogens, corticosteroids, progestins) in rivers and wastewaters by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS)

  • Sci Total Environ. 2018 Jan 1;610-611:1164-1172. doi: 10.1016/j.scitotenv.2017.08.114.
Kun Zhang 1 Karl Fent 2
Affiliations

Affiliations

  • 1 University of Applied Sciences and Arts Northwestern Switzerland, School of Life Sciences, Gründenstrasse 40, CH-4132 Muttenz, Switzerland.
  • 2 University of Applied Sciences and Arts Northwestern Switzerland, School of Life Sciences, Gründenstrasse 40, CH-4132 Muttenz, Switzerland; Swiss Federal Institute of Technology Zürich (ETH Zürich), Department of Environmental Systems Science, Institute of Biogeochemistry and Pollution Dynamics, CH-8092 Zürich, Switzerland. Electronic address: [email protected].
Abstract

A highly sensitive and robust method was developed for routine analysis of two progestin metabolites, 17α-hydroxypregnanolone (17OH-Δ5P) and pregnanediol (PD), and 31 other natural and synthetic Steroids and related metabolites (estrogens, androgens, corticosteroids, progestins) in river water, as well as influents and effluents of municipal wastewater treatment Plants (WWTP) using HPLC-MS/MS combined with solid-phase extraction. For the various matrixes considered, the optimized method showed satisfactory performance with recoveries of 70-120% for most of target Steroids. The method detection limits (MDLs) ranged from 0.01 to 3ng/L for river water, 0.02 to 10ng/L for WWTP effluents, and 0.1 to 40ng/L for influents with good linearity and reproducibility. The developed method was successfully applied for the analysis of Steroids in rivers and WWTP influent and effluents. WWTP influents concentrations of 17OH-Δ5P and PD were 51-256ng/L and up to 400ng/L, respectively, along with androstenedione (concentration range: 38-220ng/L), testosterone (11-26ng/L), estrone (2.3-37ng/L), 17β-estradiol (N.D.-8.7ng/L), 17α-hydroxyprogesterone (N.D.-66ng/L), medroxyprogesterone acetate (N.D.-5.3ng/L), and progesterone (2.0-22ng/L), while only androstenedione (ADD), estrone (E1), and estriol (E3) were detected in effluent with concentrations ranging up to 1.7ng/L, 0.90ng/L and 0.8ng/L, respectively. In river water samples, only ADD and E1 were detected with concentrations up to 1.0ng/L and 0.91ng/L. Our procedure represents the first method for analyzing 17OH-Δ5P and PD in environmental samples along with a large series of Steroids.

Keywords

Matrix effects; River water; Steroids; Trace analysis; Wastewater effluents.

Figures
Products