A new method measuring the interaction of radiotracers with the human P-glycoprotein (P-gp) transporter
- Nucl Med Biol. 2018 May;60:29-36. doi: 10.1016/j.nucmedbio.2018.02.002.
- 1. Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria; Department for Nutritional Science, University of Vienna, Vienna, Austria.
- 2. Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria.
- 3. Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria; Department of Engineering, University of Applied Sciences Wiener Neustadt, Austria.
- 4. Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria; Department of Pharmaceutical Technology and Biopharmaceuticals (PTB), University of Vienna, Vienna, Austria.
- 5. Department for Nutritional Science, University of Vienna, Vienna, Austria.
- 6. Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria; Department of Inorganic Chemistry, University of Vienna, Vienna, Austria; CBmed, Graz, Austria.
- 7. Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Medical University of Vienna, Vienna, Austria; Department of Pharmaceutical Technology and Biopharmaceuticals (PTB), University of Vienna, Vienna, Austria; Ludwig Boltzmann Institute Applied Diagnostics, Vienna, Austria. Electronic address: [email protected].
In drug development, biomarkers for cerebral applications have a lower success rate compared to cardiovascular drugs or tumor therapeutics. One reason is the missing blood brain barrier penetration, caused by the tracer's interaction with efflux transporters such as the P-gp (MDR1 or ABCB1). Aim of this study was the development of a reliable model to measure the interaction of radiotracers with the human efflux transporter P-gp in parallel to the radiolabeling process. LigandTracer® Technology was used with the wildtype cell line MDCKII and the equivalent cell line overexpressing human P-gp (MDCKII-hMDR1). The method was evaluated based on established PET tracers with known interaction with the human P-gp transporter and in nanomolar concentration (15 nM). [11C]SNAP-7941 and [18F]FE@SNAP were used as P-gp substrates by comparing the real-time model with an uptake assay and μPET images. [11C]DASB [11C]Harmine, [18F]FMeNER,[18F]FE@SUPPY and [11C]Me@HAPTHI were used as tracers without interactions with P-gp in vitro. However, [11C]Me@HAPTHI shows a significant increase in SUV levels after blocking with Tariquidar. The developed real-time kinetic model uses directly PET tracers in a compound concentration, which is reflecting the in vivo situation. This method may be used at an early stage of radiopharmaceutical development to measure interactions to P-gp before conducting animal experiments.
-
Cat. No.Product NameDescriptionTargetResearch Area
-
target: P-glycoproteinResearch Areas: Cancer
-
Research Areas: Cancer