Human Neutrophil Negative Selection Kit
MCE Human Neutrophil Negative Selection Kit can isolate neutrophils from fresh peripheral blood. The principle involves using biotin-labeled monoclonal antibodies to label non-target cells, followed by the removal of these non-target cells through streptavidin-labeled magnetic beads, achieving the selective isolation of human neutrophils.
-
Storage :
4°C, 2 years
Do not freeze the magnetic beads
- Manual (2938KB)
- COA
Description & Advantages
MCE Human Neutrophil Negative Selection Kit can isolate neutrophils from fresh peripheral blood. The principle involves using biotin-labeled monoclonal antibodies to label non-target cells, followed by the removal of these non-target cells through streptavidin-labeled magnetic beads, achieving the selective isolation of human neutrophils.
Features of MCE Human Neutrophil Negative Selection Kit:
1. Simple and Rapid: No separation columns are required. Cell isolation can be completed using only a magnetic separator.
2. High Purity: Optimized magnetic capture enables efficient enrichment, yielding up to 95% purity of isolated cells.
3. High Cell Viability: The isolated cells are free of antibody and magnetic bead labeling, maintaining high viability and normal cellular functions for downstream applications.
Protocol
Recommended Buffer (Not Provided)
| Buffer | Composition |
|---|---|
| Isolation Buffer | PBS, 0.5% BSA, 2 mM EDTA, pH 7.0-7.4 |
Note: a. BSA may be replaced with human serum albumin (HSA) or 2% fetal bovine serum (FBS);
b. It is recommended to prepare the Isolation Buffer with water for injection, sterilize it through a 0.22 μm filter, and store it at 4°C.
Example: Isolation of human neutrophils from a fresh human peripheral-blood leukocyte suspension
1. Prepare a single-cell suspension from a fresh human peripheral-blood leukocyte suspension. Remove red blood cells as appropriate, resuspend the cells in PBS, filter through a 70 μm cell strainer, and count the cells. Centrifuge at 500 × g for 5 min and discard the supernatant.
Note: This step removes cell clumps or tissue debris that may affect separation purity.
2. Resuspend the cells in Isolation Buffer and adjust the cell density to 1 × 108 cells/mL.
3. Transfer 100 μL of cell suspension (1 × 107 cells) to the bottom of a sterile centrifuge tube. Add 2 μL Biotin-Antibody Mix, mix thoroughly, and incubate at 4°C for 10 min.
Note: a. Add the cell suspension directly to the bottom of the tube rather than along the tube wall;
b. Scale the amount of Biotin-Antibody Mix proportionally for larger cell numbers.
4. Preparation of Streptavidin Magnetic Beads: thoroughly resuspend the beads and transfer 20 μL to a 1.5 mL microcentrifuge tube. Add 1 mL Isolation Buffer, mix, centrifuge at 10,000 × g for 1 min, and discard the supernatant. Repeat the wash 1-2 times and finally resuspend the beads in 20 μL Isolation Buffer.
Note: The final volume of Isolation Buffer used to resuspend the beads should equal the initial bead volume.
5. After antibody incubation, add 20 μL of pre-washed Streptavidin Magnetic Beads, mix thoroughly, and incubate at 4°C for 10 min.
Note: Scale reagent amounts proportionally for larger cell numbers. For fewer than 1 × 107 cells, adjust the cell suspension volume to 100 μL and use 2 μL Biotin-Antibody Mix and 20 μL beads.
6. Add 2.5 mL Isolation Buffer and mix gently, avoiding vigorous vortexing or repeated pipetting.
7. Place the tube on a magnetic separation rack and allow it to stand for 5 min.
8. While the tube remains on the magnetic rack, carefully collect the cell suspension into a new sterile centrifuge tube. The suspension contains enriched human neutrophils. Centrifuge at 300 × g for 5 min, discard the supernatant, and collect the cells.
Note: Avoid touching the beads with the pipette tip; the cell suspension may also be collected by pouring.
9. Wash the cells as required and resuspend them in an appropriate buffer or culture medium. The isolated cells may be used for downstream molecular or cellular experiments.
Storage
4°C, 2 years
Do not freeze the magnetic beads
Attention
1. Use low-retention pipette tips and tubes whenever possible to minimize bead and antibody loss due to surface adsorption.
2. Avoid high-speed centrifugation, drying, or freezing of the magnetic beads during storage and handling.
3. Do not leave the magnetic beads in a magnetic field for extended periods, as this may cause bead aggregation and reduced binding activity.
4. Thoroughly resuspend the beads before use. Handle gently throughout the procedure and avoid generating excessive bubbles.
5. This product must be used with a compatible magnetic separator.
6. Perform all procedures gently to minimize mechanical stress and maintain cell viability.
7. This product is for R&D use only, not for drug, household, or other uses.
8. For your safety and health, please wear a lab coat and disposable gloves to operate. /p>
Components
| Components | HY-K0359-0.2 mL (For 1 × 108 cells) |
HY-K0359-1 mL (For 5 × 108 cells) |
HY-K0359-2 mL (For 1 × 109 cells) |
|---|---|---|---|
| Biotin-Antibody Mix | 20 μL | 100 μL | 200 μL |
| Streptavidin Magnetic Beads | 0.2 mL | 1 mL | 1 mL × 2 |