Vari Fluor 620 TSA, 200× (same as mIHC kit)
Vari Fluor 620 TSA, 200× (same as mIHC kit) (VF 620 mIHC) is suitable for multicolor immunohistochemistry experiments and are compatible with the dyes in multicolor immunohistochemistry kits (Ex/Em = 590/620 nm).
商品は「研究用試薬」です。人や動物の医療用・臨床診断用・食品用の製品ではありません。
研究用途以外に使用した場合、当社は一切の責任を負いかねます。
-
保管条件:
Please store the product under the recommended conditions in the Certificate of Analysis.
生物活性
製品説明
体外実験
Remove the dye and dilute it using a dedicated dye diluent Tyramide Amplification Buffer (HY-D1840) (sold separately). The TSA fluorescent dye working solution is prepared as follows: VF fluorescent dye + TSA buffer. The recommended dilution ratio for the fluorescent dye and TSA buffer is 1:200. The dilution ratio can be flexibly adjusted and optimized based on specific conditions; the optimal range is 1:50 to 1:400; Generally, if the primary antibody incubation time is 1-3 hours at room temperature, a dilution ratio of 1:50-1:200 is recommended; if the primary antibody is incubated overnight at 4°C (12 hours or longer), a dilution ratio of 1:200-1:400 or higher is recommended.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only. Further protocols information, click here.
化学情報
-
SMILES
[Vari Fluor 620 TSA, 200?(same as mIHC kit)]
-
別名
VF 620 mIHC
-
輸送条件
Room temperature in continental US; may vary elsewhere.
-
保管条件
Please store the product under the recommended conditions in the Certificate of Analysis.
プロトコル
-
Multiplex immunofluorescence IHC
Multiplex immunofluorescence IHC detects multiple protein biomarkers in one tissue section by sequential antibody staining, HRP-mediated tyramide fluorophore deposition, heat-mediated antibody stripping, nuclear counterstaining, multispectral imaging, spectral unmixing, and digital cell phenotyping; TSA deposits fluorophore near the antigen so the fluorescence signal remains after primary and secondary antibodies are removed, enabling repeated staining cycles, including with antibodies from the same host species. Classic FFPE tumor immune-profiling applications use panels such as CD3, CD8, CD68/CD163, FOXP3, PD-1, PD-L1, pancytokeratin, Ki67, and DAPI to identify tumor cells, immune-cell subsets, checkpoint-marker expression, co-expression phenotypes, cell density, and spatial relationships in the tumor microenvironment.
-
Polymer-Based Two-Step IHC Detection
Polymer-based two-step IHC detects tissue antigens by first binding an unlabeled primary antibody to the antigen and then applying an HRP-polymer secondary reagent that carries multiple secondary antibodies and HRP molecules on a polymer backbone; the localized HRP converts chromogens such as DAB or AEC into visible deposits for light-microscopic interpretation. The method is \"two-step\" because the primary antibody step is followed directly by the polymer-enzyme secondary reagent, rather than by separate secondary-antibody and avidin-biotin complex steps; published comparisons reported similar or higher sensitivity than several multistep systems and avoidance of endogenous-biotin interference.
-
Avidin-Biotin/Streptavidin-Biotin IHC
Avidin-biotin or streptavidin-biotin immunohistochemistry detects tissue antigens by binding a primary antibody to the target antigen, then detecting that antibody with a biotinylated antibody and an avidin-biotin-enzyme or streptavidin-enzyme detection complex; the enzyme reaction produces a visible chromogenic deposit at the antigen site for light-microscopic localization. The classic ABC method uses the high-affinity avidin-biotin interaction to bridge biotinylated secondary antibody and biotinylated peroxidase, and early comparative studies reported stronger immunoperoxidase staining than PAP-based methods in formalin-fixed tissue sections.
-
Multiplex immunohistochemistry
Multiplex immunohistochemistry (mIHC), also known as tyramide dignal amplification (TSA), is an enzymatic detection method that uses horseradish peroxidase (HRP) to perform high-density in-situ labeling of target proteins or nucleic acids.
純度とドキュメンテーション
Calculators
濃度 (開始) × 体積 (開始) = 濃度 (終了) × 体積 (終了)