On-Line Solid Phase Extraction High Performance Liquid Chromatography Method Coupled With Tandem Mass Spectrometry for the Therapeutic Monitoring of Cannabidiol and 7-Hydroxy-cannabidiol in Human Serum and Saliva

  • Front Pharmacol. 2022 Jun 22:13:915004. doi: 10.3389/fphar.2022.915004.
Valentina Franco  1  2 Michela Palmisani  2 Roberto Marchiselli  1 Francesca Crema  1 Cinzia Fattore  2 Valentina De Giorgis  2 Costanza Varesio  2  3 Paola Rota  4 Vincenza Flora Dibari  5 Emilio Perucca  6  7
Affiliations
  • 1. Department of Internal Medicine and Therapeutics, Clinical and Experimental Pharmacology Unit, University of Pavia, Pavia, Italy.
  • 2. IRCCS Mondino Foundation, Pavia, Italy.
  • 3. Department of Brain and Behavioral Sciences, University of Pavia, Pavia, Italy.
  • 4. Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.
  • 5. B.S.N. Srl R&D Laboratory, Castelleone, Italy.
  • 6. Department of Medicine, Austin Health, The University of Melbourne, Melbourne, VIC, Australia.
  • 7. Department of Neuroscience, Monash University, Melbourne, VIC, Australia.
Abstract

Cannabidiol is a novel antiseizure medication approved in Europe and the US for the treatment of seizures associated with Lennox-Gastaut syndrome, Dravet syndrome and tuberous sclerosis complex. We describe in this article a new and simple liquid chromatography-mass spectrometry method (LC-MS/MS) for the determination of cannabidiol and its active metabolite 7-hydroxy-cannabidiol in microvolumes of serum and saliva (50 μl), to be used as a tool for therapeutic drug monitoring (TDM) and pharmacokinetic studies. After on-line solid phase extraction cannabidiol, 7-hydroxy-cannabidiol and the internal standard cannabidiol-d3 are separated on a monolithic C18 column under gradient conditions. Calibration curves are linear within the validated concentration range (10-1,000 ng/ml for cannabidiol and 5-500 ng/ml for 7-hydroxy-cannabidiol). The method is accurate (intraday and interday accuracy within 94-112% for cannabidiol, 91-109% for 7-hydroxy-cannabidiol), precise (intraday and interday precision <11.6% for cannabidiol and <11.7% for 7- hydroxy-cannabidiol) and sensitive, with a LOQ of 2.5 ng/ml for cannabidiol and 5 ng/ml for 7-hydroxy-cannabidiol. The stability of the analytes was confirmed under different storage conditions. Extraction recoveries were in the range of 81-129% for cannabidiol and 100-113% for 7-hydroxy-cannabidiol. The applicability of the method to TDM was demonstrated by analysis of human serum and saliva samples obtained from patients with epilepsy treated with cannabidiol.

Keywords
7-hydroxy-cannabidiol; HPLC-MS/MS; antiseizure medications; cannabidiol; on-line solid phase extraction; saliva; serum.
Products