Fluo-3AM (solution)
Based on 1 Customer Validation
Fluo-3AM (solution) is a fluorecent Ca2+ chelator, with high affinity for calcium. Fluo-3 AM can specifically identify intracellular calcium ions, with high sensitivity, low cytotoxicity, increased AM acetylmethyl ester can enter the cell well, after being sheared by the intracellular esterase stay in the cell to bind to calcium ions, produce strong fluorescence.
Solvent and concentration: DMSO: 5 mM
For research use only. We do not sell to patients.
- CAS No.: 121714-22-5
- Formula: C51H50Cl2N2O23
- Molecular Weight:1129.85
-
Storage:
Please store the product under the recommended conditions in the Certificate of Analysis.
Biological Activity
Description
Solvent and concentration: DMSO: 5 mM
In Vitro
Guide (The following is our recommended protocol. This protocol is only a guide and should be modified according to your specific needs).
1. Preparation of Fluo-3 AM working solution
1.1 Preparation of Fluo-3 AM working solution
Dilute the stock solution in HBSS to obtain 1-10 μM of working solution.
Note: Please adjust the concentration of Fluo-3 AMworking solution according to the actual situation.
2. Cell staining
2.1 Suspension cells (6-well plate)
2.1.1 Centrifuge at 1000 g at 4°C for 3-5 minutes and then discard the supernatant. Wash twice with PBS, 5 minutes each time. The cell density is 1×106/mL
2.1.2 Add 1 mL of working solution, and then incubate at room temperature for 5-30 minutes.
2.1.3 Centrifuge at 400 g at 4°C for 3-4 minutes and then discard the supernatant.
2.1.4 Wash twice with PBS, 5 minutes each time.
2.1.5 Resuspend cells with serum-free cell culture medium or PBS. Observation by fluorescence microscopy or flow cytometry.
2.2 Adherent cells
2.2.1 Culture adherent cells on sterile coverslips.
2.2.2 Remove the coverslip from the medium and aspirate excess medium.
2.2.3 Add 100 μL of working solution, gently shake it to completely cover the cells, and then incubate at room temperature for 5-30 minutes.
2.2.4 Wash twice with medium, 5 minutes each time. Observation by fluorescence microscopy.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only. Further protocols information, click here.
Chemical Information
-
CAS No. 121714-22-5
-
Appearance Liquid (Density: 1.492±0.1 g/cm3)
-
Molecular Weight 1129.85
-
Formula C51H50Cl2N2O23
-
Color Pink to red
-
SMILES
ClC(C=C1C(C2=CC(OCCOC(C=C(C)C=C3)=C3N(CC(OCOC(C)=O)=O)CC(OCOC(C)=O)=O)=C(N(CC(OCOC(C)=O)=O)CC(OCOC(C)=O)=O)C=C2)=C(C=C4Cl)C5=CC4=O)=C(C=C1O5)OCOC(C)=O
-
Synonyms
Fluo-3-pentaacetoxymethyl ester (solution)
-
Shipping
Room temperature in continental US; may vary elsewhere.
-
Storage
Please store the product under the recommended conditions in the Certificate of Analysis.
Protocols
-
Cell Cytotoxicity Assay
Cytotoxicity assays are usually based on the assessment of cell membrane damage, which can also be indirectly detected by measuring cell viability. Detection methods include MTT assay, CKK-8 assay, LDH assay and ATP assay, etc.
-
Mammalian live/dead viability and cytotoxicity staining
Live/dead viability and cytotoxicity staining assays are based on the simultaneous detection of intracellular esterase activity in metabolically active (viable) cells and membrane integrity loss in non-viable cells. In commonly used dual-staining approaches, membrane-permeant fluorogenic substrates are converted by intracellular esterases into fluorescent products in live cells, while impermeant DNA-binding dyes selectively enter cells with compromised plasma membranes and label nucleic acids in dead or dying cells, enabling discrimination between viable and non-viable populations by fluorescence microscopy or flow cytometry.
-
Calcium Spark Assay
Calcium sparks are localized, transient increases in intracellular calcium concentration ([Ca2+]i) that occur in cardiac myocytes and represent elementary events underlying excitation-contraction coupling. These events are generated by the coordinated opening of clusters of ryanodine receptors (RyRs) on the sarcoplasmic reticulum membrane, leading to a brief release of Ca2+ into the cytosol. The detection and analysis of calcium sparks provide insights into the mechanisms of calcium handling and signaling in cardiac cells. Imaging techniques using fluorescent calcium indicators such as Fluo-3 are employed to visualize these subcellular calcium transients with high spatial and temporal resolution. The protocol is based on established methodologies described in primary literature for both experimental measurement and automated analysis of calcium sparks.
-
Ca2+ Staining Technique
Ca2+ staining is an experimental technique that utilizes specific fluorescent probes (such as Fluo-4 AM, Fura-2, etc.) to qualitatively or quantitatively detect dynamic changes in intracellular Ca2+ concentrations; this is achieved by monitoring the changes in fluorescent signals generated when these probes bind to free intracellular calcium ions. The underlying principle relies primarily on the presence of chelating groups within the probe's molecular structure that possess high affinity for calcium ions.
-
Cell Viability Determination by MTT Colorimetric Assay
The following protocol uses the MTT colorimetric assay as a classic literature-established method for assessing cell viability/metabolic activity in cultured mammalian cells. MTT[3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide] is reduced by metabolically active cells to a colored formazan product; the amount of formazan is quantified spectrophotometrically and provides an indirect measure of metabolically active viable cells. Importantly, MTT reduction reflects cellular oxidoreductase/metabolic activity rather than an absolute direct count of living cells, so changes in cellular metabolism can alter the signal independently of cell number.
Purity & Documentation
-
Data Sheet (280 KB)
-
SDS (252 KB)
- English - EN (252 KB)
- Français - FR (252 KB)
- Deutsch - DE (252 KB)
- Norwegian - NO (252 KB)
- Español - ES (252 KB)
- Swedish - SV (252 KB)
- Italian - IT (252 KB)
- Korean - KR (252 KB)
- Portuguese - PT (252 KB)
-
Handling Instructions (2659 KB)
References
Calculators
Concentration (start) × Volume (start) = Concentration (final) × Volume (final)