Stereoselective method to quantify bupropion and its three major metabolites, hydroxybupropion, erythro-dihydrobupropion, and threo-dihydrobupropion using HPLC-MS/MS
- J Chromatogr B Analyt Technol Biomed Life Sci. 2016 Mar 15;1015-1016:201-208. doi: 10.1016/j.jchromb.2016.02.018.
- 1. Indiana University School of Medicine, Indiana University Melvin and Bren Simon Cancer Center, RR208, 699 Riley Hospital Drive, Indianapolis, IN 46202, United States. Electronic address: [email protected].
- 2. Phenomenex, 411 Madrid Avenue, Torrance, CA 90501, United States. Electronic address: [email protected].
- 3. Department of Medicine, Division of Clinical Pharmacology, RR 208, 699 Riley Hospital Drive, Indianapolis, IN 46202, United States. Electronic address: [email protected].
- 4. Department of Medicine, Division of Clinical Pharmacology, R2 402, 950 West Walnut Avenue, Indianapolis, IN 46202, United States. Electronic address: [email protected].
Bupropion metabolites formed via oxidation and reduction exhibit pharmacological activity, but little is known regarding their stereoselective disposition. A novel stereoselective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed to separate and quantify enantiomers of bupropion, 4-hydroxybupropion, and erythro- and threo-dihydrobupropion. Liquid-liquid extraction was implemented to extract all analytes from 50 μL human plasma. Acetaminophen (APAP) was used as an internal standard. The analytes were separated on a Lux 3 μ Cellulose-3 250×4.6 mm column by methanol: acetonitrile: ammonium bicarbonate: ammonium hydroxide gradient elution and monitored using an ABSciex 5500 QTRAP triple-quadrupole mass spectrometer equipped with electrospray ionization probe in positive mode. Extraction efficiency for all analytes was ≥70%. The stability at a single non-extracted concentration for over 48 h at ambient temperature resulted in less than 9.8% variability for all analytes. The limit of quantification (LOQ) for enantiomers of bupropion and 4-hydroxybupropion was 0.3 ng/mL, while the LOQ for enantiomers of erythro- and threo-hydrobupropion was 0.15 ng/mL. The intra-day precision and accuracy estimates for enantiomers of bupropion and its metabolites ranged from 3.4% to 15.4% and from 80.6% to 97.8%, respectively, while the inter-day precision and accuracy ranged from 6.1% to 19.9% and from 88.5% to 99.9%, respectively. The current method was successfully implemented to determine the stereoselective pharmacokinetics of bupropion and its metabolites in 3 healthy volunteers administered a single 100mg oral dose of racemic bupropion. This novel, accurate, and precise HPLC-MS/MS method should enhance further research into bupropion stereoselective metabolism and drug interactions.
-
Cat. No.Product NameDescriptionTargetResearch Area
-
target: Drug MetaboliteResearch Areas: Neurological Disease
-
target: Drug MetaboliteResearch Areas: Neurological Disease
-
Research Areas: Neurological Disease