Dimethyl sulfoxide (suitable for HPLC)
Based on 1 Customer Validation
Dimethyl sulfoxide (suitable for HPLC) is an aprotic solvent that can dissolve water-insoluble therapeutic and toxic agents. Dimethyl sulfoxide (DMSO) has a strong affinity for water and has the ability to rapidly penetrate or enhance the penetration of other substances through biological membranes. Dimethyl sulfoxide also has potential free radical scavenging and anticholinesterase effects and may affect coagulation activity. Dimethyl sulfoxide also induces histamine release from mast cells but is thought to have low systemic toxicity. Dimethyl sulfoxide (suitable for HPLC) is suitable for HPLC.
For research use only. We do not sell to patients.
- Purity : 99.86%
- CAS No.: 67-68-5
- Formula: C2H6OS
- Molecular Weight:78.13
-
Storage:
Please store the product under the recommended conditions in the Certificate of Analysis.
Biological Activity
Description
In Vitro
Dimethyl sulfoxide (DMSO) is a colorless liquid. Dimethyl sulfoxide is a polar, aprotic solvent miscible with water and able to dissolve an enormous catalog of polar and nonpolar small molecules.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only. Further protocols information, click here.
Chemical Information
-
CAS No. 67-68-5
-
Appearance Liquid
-
Molecular Weight 78.13
-
Formula C2H6OS
-
Color Colorless to light yellow
-
SMILES
O=S(C)C
-
Shipping
Room temperature in continental US; may vary elsewhere.
-
Storage
Please store the product under the recommended conditions in the Certificate of Analysis.
Solvent & Solubility
In Vitro:
H2O : 25 mg/mL (319.98 mM; Need ultrasonic)
Protocols
-
Subchronic/Chronic Toxicity Study
A subchronic/chronic oral toxicity study detects systemic adverse effects caused by repeated administration of a test article, using mortality, clinical signs, body weight, food/water intake, ophthalmology, urinalysis, hematology, serum biochemistry, organ weights, gross necropsy, and histopathology as integrated readouts. The readout reflects dose-related physiological injury, target-organ pathology, reversibility after recovery, and derivation of NOAEL, LOAEL, or related point-of-departure values when the dataset supports them.
-
Acute Systemic Toxicity Study
Acute systemic toxicity studies evaluate adverse effects occurring after a single exposure, or repeated exposure within a short acute window, and the main in vivo readouts are mortality, moribund condition, clinical signs, body-weight change, and gross pathological findings; acute oral toxicity methods were developed to replace classical LD50 testing with reduced-animal designs such as fixed-dose procedure, acute toxic class method, and up-and-down procedure. The fixed-dose procedure classifies acute toxicity by administering predefined dose levels and observing evident toxicity rather than using death as the primary endpoint, whereas the acute toxic class method uses sequential groups of three animals per step and the up-and-down procedure doses animals sequentially to estimate an LD50 with fewer animals than conventional LD50 testing.
Purity & Documentation
-
Data Sheet (272 KB)
-
SDS (394 KB)
- English - EN (394 KB)
- Français - FR (394 KB)
- Deutsch - DE (394 KB)
- Norwegian - NO (394 KB)
- Español - ES (394 KB)
- Swedish - SV (394 KB)
- Italian - IT (394 KB)
- Korean - KR (394 KB)
- Portuguese - PT (394 KB)
-
Handling Instructions (2659 KB)
References
Calculators
Concentration (start) × Volume (start) = Concentration (final) × Volume (final)
Complete Stock Solution Preparation Table
| Optional Solvent | Concentration Solvent Mass | 1 mg | 5 mg | 10 mg | 25 mg |
|---|---|---|---|---|---|
| H2O | 1 mM | 12.7992 mL | 63.9959 mL | 127.9918 mL | 319.9795 mL |
| 5 mM | 2.5598 mL | 12.7992 mL | 25.5984 mL | 63.9959 mL | |
| 10 mM | 1.2799 mL | 6.3996 mL | 12.7992 mL | 31.9980 mL | |
| 15 mM | 0.8533 mL | 4.2664 mL | 8.5328 mL | 21.3320 mL | |
| 20 mM | 0.6400 mL | 3.1998 mL | 6.3996 mL | 15.9990 mL | |
| 25 mM | 0.5120 mL | 2.5598 mL | 5.1197 mL | 12.7992 mL | |
| 30 mM | 0.4266 mL | 2.1332 mL | 4.2664 mL | 10.6660 mL | |
| 40 mM | 0.3200 mL | 1.5999 mL | 3.1998 mL | 7.9995 mL | |
| 50 mM | 0.2560 mL | 1.2799 mL | 2.5598 mL | 6.3996 mL | |
| 60 mM | 0.2133 mL | 1.0666 mL | 2.1332 mL | 5.3330 mL | |
| 80 mM | 0.1600 mL | 0.7999 mL | 1.5999 mL | 3.9997 mL | |
| 100 mM | 0.1280 mL | 0.6400 mL | 1.2799 mL | 3.1998 mL |
* Note: If you choose water as the stock solution, please dilute it to the working solution, then filter and sterilize it with a 0.22 μm filter before use.