DU717
DU-717 is an antihypertensive agent.
商品は「研究用試薬」です。人や動物の医療用・臨床診断用・食品用の製品ではありません。
研究用途以外に使用した場合、当社は一切の責任を負いかねます。
- CAS 番号: 59943-31-6
- 分子式: C12H15ClN4O2S
- 分子量:314.79
-
保管条件:
Please store the product under the recommended conditions in the Certificate of Analysis.
Endogenous Metabolite アイソフォーム固有の製品をすべて表示
More
生物活性
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
化学情報
-
CAS 番号 59943-31-6
-
分子量 314.79
-
分子式 C12H15ClN4O2S
-
SMILES
CN1CCN(C2=NC3=CC=C(Cl)C=C3S(N2)(=O)=O)CC1
-
輸送条件
Room temperature in continental US; may vary elsewhere.
-
保管条件
Please store the product under the recommended conditions in the Certificate of Analysis.
プロトコル
Rats[2]
DU-717 (100mg/kg per day, p.o.)-treated SHRSP, SHRSP fed on a HFC diet (including 20% suet, 5% cholesterol and 2% cholic acid) with 1% NaCl in the drinking water, ALR and NAR, 15 rats in each group, are used for EEG recording. Rats, anesthetized with intraperitoneal injection of pentobarbital (30mg/kg), are placed in a stereotaxic frame for exposing the skull, and 6 small pores of 1mm in diameter are made by a dental drill at frontal, parietal, and occipital areas on both sides. Then, stainless steel electrodes (220μ in diameter), insulated except a small loop which is formed at the tip in order to avoid any injury to the dura and the cortex, are inserted through the pores of the skull and settled gently on the dura. Electrodes on both sides are located 2mm apart from mid-sagittal line, and frontal (F), parietal (P), occipital (O) electrodes are located 5mm, 2.5 mm, and 0mm anterior to the interauricular line, respectively. The indifferent electrode (I) is placed on the mid-sagittal line, 4mm anterior to the bregma. All electrodes are connected with insulated copper wires to a miniature receptacle, and the whole assembly is embedded in dental cement. Two weeks after the operation, EEG is repeatedly recorded for several months. When EEG is recorded, rats are in a clear plastic cage (30×40×40cm) and could move freely. EEG is recorded by a ME-920, connected to an autoanalyzer MAF-5, and a photic stimulator is MS-2PS. Monopolar (I-F, I-P, I-O), and bipolar (F-P, P-O, O-F) leading are recorded. EEG is recorded during wakefulness and drowsiness. The recording calibration is 3cm/sec and 100μV/4mm.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
純度とドキュメンテーション
参考文献
[1]. Yamaguchi T, et al. Determination of 7-chloro-3-(4-methyl-1-piperazinyl)-4h-1,2,4-benzothiadiazine-1,1-dioxide (DU-717) in plasma using electron-capture gas chromatography. J Chromatogr. 1978 Oct 11;160(1):181-90. [Content Brief]
[2]. R Horie. rats (ALR) and normotensive atherogenic rats (NAR).
Calculators
濃度 (開始) × 体積 (開始) = 濃度 (終了) × 体積 (終了)