OSIP-486823
Based on 1 Customer Validation
OSIP-486823 is a novel microtubule-interfering agent with distinct biological effects on both protein kinase G (PKG) and microtubules.
For research use only. We do not sell to patients.
- Purity: 98.0%
- CAS No.: 200803-37-8
- Formula: C29H28FNO4
- Molecular Weight:473.54
-
Storage:Powder -20°C, 3 years , 4°C, 2 years ; In solvent -80°C, 6 months , -20°C, 1 month
Biological Activity
Microtubule[1]
OSIP486823 inhibits growth and induce apoptosis in SW480 human colon cancer cells, with IC50 of 0.1 μM. OSIP-486823 (OSIP486823) causes depolymerization of microtubules in interphase cells, inhibit spindle formation in mitotic cells, and induce multinucleated cells. Exisulind and the potent synthetic derivative OSIP-486823 are members of a new class of drugs known as selective apoptotic antineoplastic drugs that target cyclic guanosine 3′,5′-monophosphate phosphodiesterases (cGMP-PDE). OSIP-486823 also disrupts microtubule polymerization, perturbs mitotic spindle function, and arrests cells in mitosis in human glioma cells[1].
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
Chemical Information
-
CAS No. 200803-37-8
-
Appearance Solid
-
Molecular Weight 473.54
-
Formula C29H28FNO4
-
Color Light yellow to yellow
-
SMILES
O=C(NCC1=CC=CC=C1)CC(C2=C/3C=CC(F)=C2)=C(C)C3=C\C4=CC(OC)=C(OC)C(OC)=C4
-
Synonyms
CP248
-
Shipping
Room temperature in continental US; may vary elsewhere.
-
Storage
Powder -20°C 3 years 4°C 2 years In solvent -80°C 6 months -20°C 1 month
Protocol
The SW480 human colon adenocarcinoma and NIH3T3 mouse fibroblast cell lines are seeded in six-well plates at a density of 3×104 per well, grown for 36 to 48 hours, and then exposed to increasing concentrations of each compound (e.g., OSIP-486823; 1, 2 and 4 μM) for 48 hours. Cell numbers are determined using a Coulter counter and results are expressed as a percentage of the control culture. All assays are done in triplicate. Data are analyzed in Excel and the IC50s are determined graphically from cell survival curves[1].
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
Purity & Documentation
-
Data Sheet (279 KB)
-
SDS (251 KB)
- English - EN (251 KB)
- Français - FR (251 KB)
- Deutsch - DE (251 KB)
- Norwegian - NO (251 KB)
- Español - ES (251 KB)
- Swedish - SV (251 KB)
- Italian - IT (251 KB)
- Korean - KR (251 KB)
- Portuguese - PT (251 KB)
-
Handling Instructions (2659 KB)
References