LUF7244
Based on 1 Customer Validation
LUF7244 is a selective allosteric modulator of Kv11.1 channels. LUF7244 inhibits early afterdepolarizations. LUF7244 can be used for anti-arrhythmia research.
For research use only. We do not sell to patients.
- Purity : 98.9%
- CAS No.: 1821638-43-0
- Formula: C20H15ClN2O3
- Molecular Weight:366.80
-
Storage:Powder -20°C, 3 years , 4°C, 2 years ; In solvent -80°C, 6 months , -20°C, 1 month
Biological Activity
Description
In Vitro
LUF7244 (0-10 μM; HEK293 cells) binds Kv11.1 channels and increases IKv11.1 by inhibiting inactivation in a dose-dependent manner[1].
LUF7244 (0-10 μM; cardiomyocytes) reduces action potential duration (APD) by approximately 50% and dofetilide-induced early afterdepolarization (EAD) in isolated ventricular CMCs from SR and CAVB dogs[1].
LUF7244 (10 μM) had no effects on IKIR2.1, INav1.5, ICa-L, and IKs but doubled IKr[1].
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only. Further protocols information, click here.
In Vivo
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
Chemical Information
-
CAS No. 1821638-43-0
-
Appearance Solid
-
Molecular Weight 366.80
-
Formula C20H15ClN2O3
-
Color White to off-white
-
SMILES
O=C(NC1=CC=CN=C1)COC2=CC=C(C(C3=CC=CC(Cl)=C3)=O)C=C2
-
Shipping
Room temperature in continental US; may vary elsewhere.
-
Storage
Powder -20°C 3 years 4°C 2 years In solvent -80°C 6 months -20°C 1 month
Protocols
-
Cardiac voltage-sensitive optical mapping
Cardiac voltage-sensitive optical mapping records changes in transmembrane potential from cardiac tissue by staining the preparation with a voltage-sensitive dye and imaging fluorescence changes during electrical activation; the resulting optical action potentials can be used to map activation time, action potential duration, conduction velocity, wavefront propagation, and arrhythmia dynamics. The optical signal represents a relative fluorescence change from a tissue volume rather than a single-cell intracellular recording, so spatial resolution, sampling rate, voltage resolution, optical magnification, light penetration, and motion control must be considered together when interpreting optical action potentials.
Purity & Documentation
-
Data Sheet (266 KB)
-
SDS (251 KB)
- English - EN (251 KB)
- Français - FR (251 KB)
- Deutsch - DE (251 KB)
- Norwegian - NO (251 KB)
- Español - ES (251 KB)
- Swedish - SV (251 KB)
- Italian - IT (251 KB)
- Korean - KR (251 KB)
- Portuguese - PT (251 KB)
-
Handling Instructions (2659 KB)
References
Calculators
Concentration (start) × Volume (start) = Concentration (final) × Volume (final)