FlCFe1
FlCFe1 is a ratiometric ferrous ion probe that enables imaging of iron distribution in 3D cell models such as tumor spheroids. The detection mechanism of FlCFe1 relies on its structure as a ratiometric analogue of Calcein-AM. FlCFe1 has an excitation wavelength of 405 nm, with emission wavelengths of 490 nm (coumarin emission signal) and 530 nm (fluorescein emission signal).
商品は「研究用試薬」です。人や動物の医療用・臨床診断用・食品用の製品ではありません。
研究用途以外に使用した場合、当社は一切の責任を負いかねます。
- 分子式: C67H71N5O27
- 分子量:1378.30
-
保管条件:
Please store the product under the recommended conditions in the Certificate of Analysis.
生物活性
製品説明
体外実験
Operating Instructions (The following is a recommended experimental protocol for guidance only, and adjustments are required based on your specific needs).
1. Staining Procedure[1]
1.1 Sample Types:
1.1.1 Adherent cells: DLD-1 colorectal adenocarcinoma cells.
1.1.2 3D multicellular model: DLD-1 tumor spheres (106 cells).
1.2 Incubation Conditions:
1.2.1 Adherent cells: Co-incubate with 10 μM FlCFe1 for 2 h.
1.2.2 Tumor spheres: Co-incubate with 10 μM FlCFe1 for 24 h.
2. Control Setup
2.1 Set up vehicle control groups for both adherent cells and tumor spheres.
2.2 Set up iron depletion control group: After incubation with FlCFe1, pretreat adherent cells with salicylaldehyde isonicotinoyl hydrazone (SIH) for 30 min.
2.3 Set up iron supplementation control group: After incubation with FlCFe1, pretreat adherent cells with ammonium ferrous sulfate (FAS) for 30 min.
3. Detection and Analysis
3.1 Instrument: Confocal fluorescence microscope
3.1.1 Excitation wavelength: 405 nm; emission wavelengths: 425-480 nm (blue channel) and 520-600 nm (yellow channel).
3.2 Result Analysis:
3.2.1 Changes in fluorescence intensity: A higher blue/yellow emission ratio indicates a higher level of labile iron pool (LIP), while a lower ratio indicates a lower LIP level.
3.2.2 Fluorescence localization: Localizes to the cytoplasm in adherent cells, with no specific organelle targeting.
3.2.3 Penetration in 3D model: FlCFe1 can penetrate tumor spheres up to 200 μm, enabling ratio-based LIP detection throughout the entire tumor sphere.
3.2.4 Response to iron chelator: The iron chelator only reduces the blue/yellow ratio in the approximately 20 μm outer region of tumor spheres.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only. .
化学情報
-
分子量 1378.30
-
分子式 C67H71N5O27
-
SMILES
CCN(C1=CC2=C(C=C(C(O2)=O)C(NC3CCC(CC3)NC(C4=CC5=C(C6(C7=C(C(CN(CC(OCOC(C)=O)=O)CC(OCOC(C)=O)=O)=C(C=C7)OC(C)=O)OC8=C6C=CC(OC(C)=O)=C8CN(CC(OCOC(C)=O)=O)CC(OCOC(C)=O)=O)OC5=O)C=C4)=O)=O)C=C1)CC
-
輸送条件
Room temperature in continental US; may vary elsewhere.
-
保管条件
Please store the product under the recommended conditions in the Certificate of Analysis.
純度とドキュメンテーション
参考文献
Calculators