Margatoxin
Based on 1 publication(s) in Google Scholar
Margatoxin, an alpha-KTx scorpion toxin, is a high affinity inhibitor of Kv1.3 (Kd=11.7 pM). Margatoxin inhibits the Kv1.2 (Kd=6.4 pM) and Kv1.1 (Kd=4.2 nM). Margatoxin, a 39 amino-acid-long peptide, is isolated from the venom of the scorpion Centruroides margaritatus and widely used in ion channel research.
商品は「研究用試薬」です。人や動物の医療用・臨床診断用・食品用の製品ではありません。
研究用途以外に使用した場合、当社は一切の責任を負いかねます。
- 純度 : 99.17%
- CAS 番号: 145808-47-5
- 分子式: C178H286N52O50S7
- 分子量:4178.95
-
保管条件:
Sealed storage, away from moisture and light, under nitrogen.
Powder -80°C, 2 years , -20°C, 1 year* In solvent : -80°C, 6 months; -20°C, 1 month (sealed storage, away from moisture and light, under nitrogen)
MedChemExpress(MCE)の使用を引用している文献 Margatoxin
More
生物活性
製品説明
IC50 & Target
Kd: 11.7 pM (Kv1.3), 6.4 pM (Kv1.2) and 4.2 nM (Kv1.1)[1]
体内実験
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
化学情報
-
CAS 番号 145808-47-5
-
性状 Solid
-
分子量 4178.95
-
分子式 C178H286N52O50S7
-
Color White to off-white
-
別名
マルガトキシン
-
配列
Thr-Ile-Ile-Asn-Val-Lys-Cys-Thr-Ser-Pro-Lys-Gln-Cys-Leu-Pro-Pro-Cys-Lys-Ala-Gln-Phe-Gly-Gln-Ser-Ala-Gly-Ala-Lys-Cys-Met-Asn-Gly-Lys-Cys-Lys-Cys-Tyr-Pro-His (Disulfide bridge:Cys7-Cys29;Cys13-Cys34;Cys17-Cys36)
-
シーケンスの短縮
TIINVKCTSPKQCLPPCKAQFGQSAGAKCMNGKCKCYPH(Disulfide bridge:Cys7-Cys29;Cys13-Cys34;Cys17-Cys36)
-
Structure Classification
-
Initial Source
Centruroides margaritatus
-
輸送条件
Room temperature in continental US; may vary elsewhere.
-
保管条件
Sealed storage, away from moisture and light, under nitrogen
Powder -80°C 2 years -20°C 1 year * In solvent : -80°C, 6 months; -20°C, 1 month (sealed storage, away from moisture and light, under nitrogen)
Publications (1)
-
Journal Impact Factor
-
Most Recent
-
Cell Death Discov
Therapeutic potential of voltage-dependent potassium channel subtype 1.3 blockade in alleviating macrophage-related renal inflammation and fibrogenesis. [Abstract]2025 May 5;11(1):218. PMID: 40324999
溶剤 & 溶解度
体外:
DMSO : ≥ 2 mg/mL (0.48 mM; Hygroscopic DMSO has a significant impact on the solubility of product, please use newly opened DMSO)
* "≥" means soluble, but saturation unknown.
プロトコル
-
Two-electrode voltage clamp in Xenopus oocytes
Two-electrode voltage clamp measures whole-oocyte membrane current from Xenopus oocytes expressing exogenous ion channels, receptors, or transporters; one intracellular microelectrode senses membrane voltage, and the second injects current so the amplifier can hold the membrane at command voltages while recording the compensating current as the functional readout. The method is suited to Xenopus oocytes because their large size supports microinjection and intracellular electrode impalement, but the large membrane area can limit voltage-clamp speed and accuracy, especially for large or fast currents.
純度とドキュメンテーション
-
データシート (294 KB)
-
SDS (393 KB)
- English - EN (393 KB)
- Français - FR (393 KB)
- Deutsch - DE (393 KB)
- Norwegian - NO (393 KB)
- Español - ES (393 KB)
- Swedish - SV (393 KB)
- Italian - IT (393 KB)
- Korean - KR (393 KB)
- Portuguese - PT (393 KB)
-
取扱説明書 (2659 KB)
参考文献
[1]. Bartok A, et al. Margatoxin is a non-selective inhibitor of human Kv1.3 K+ channels. Toxicon. 2014 Sep;87:6-16. [Content Brief]
[2]. Chen YC, et al. PreImplantation factor prevents atherosclerosis via its immunomodulatory effects without affecting serum lipids. Thromb Haemost. 2016 May 2;115(5):1010-24. [Content Brief]