BCECF (solution)
BCECF (solution) (2′,7′-Bis(2-carboxyethyl)-5(6)-carboxyfluorescein (solution)) is a cell-impermeant pH-sensitive fluorescent dye. BCECF allows measurements in the physiological pH range 6.0-8.0. Excitation ratio: 490/440 nm; Emission intensity: 535 nm.
Solvent and concentration: DMSO: 10 mM
연구목적의 판매만을 진행합니다. 환자를 대상으로 한 판매는 하지 않습니다.
- CAS No.: 85138-49-4
- 화학식: C54H40O22
- 분자량:1040.88
-
보관:
Please store the product under the recommended conditions in the Certificate of Analysis.
Biological Activity
Solvent and concentration: DMSO: 10 mM
Guide (The following is our recommended solution. This solution is merely a guideline and should be modified according to your specific needs.)
Prepare a 5-10 μM dye solution in the buffer (recommended is a serum-free HEPES buffer containing 0.1-0.2% BSA, with a pH of 7.4). (BCECF can be introduced into the cells by methods such as patch clamp and microinjection.)
2. Add 1000 μL per well (for 6-well plate), 100 μL per well (for 96-well plate), or 25 μL per well (for 384-well plate) of the BCECF staining solution to the cell-containing cell plate.
3. Place the dye loading plate in a cell culture box and incubate it in the dark for approximately 30 minutes (at 37°C and 5% CO?); after the incubation is complete, wash the cells twice with preheated PBS/buffer to remove the extracellular free dye, and then add preheated culture medium and continue incubation for 10-15 minutes to ensure that the intracellular AM groups are completely hydrolyzed.
4. By monitoring the fluorescence at Ex/Em = 490/535 nm (pH-sensitive) and 430/535 nm (pH-insensitive reference), the F???/F??? ratio is calculated to determine the pH; for each experiment, a standard curve needs to be established using a high-potassium buffer solution containing nigericin (pH gradient from 6.0 to 8.0) to achieve quantitative detection.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
Chemical Information
-
CAS No. 85138-49-4
-
분자량 1040.88
-
화학식 C54H40O22
-
SMILES
O=C(O)CCC1=CC(C23OC(C4=C2C=CC(C(O)=O)=C4)=O)=C(OC5=C3C=C(CCC(O)=O)C(O)=C5)C=C1O.O=C(O)CCC6=CC(C78OC(C9=C7C=C(C(O)=O)C=C9)=O)=C(OC%10=C8C=C(CCC(O)=O)C(O)=C%10)C=C6O
-
Synonyms
2′,7′-Bis(2-carboxyethyl)-5(6)-carboxyfluorescein (solution)
-
선적
Room temperature in continental US; may vary elsewhere.
-
보관
Please store the product under the recommended conditions in the Certificate of Analysis.
순도&문서
References
Calculators
Concentration (start) × Volume (start) = Concentration (final) × Volume (final)