CS790AM
CS790AM (Coppersensor 790 acetoxymethyl ester) is a cell-permeable, Cu+-targeted near-infrared fluorescent probe (λabs=760 nm, λem=790 nm) applicable to live cells. CS790AM can cross lipophilic cell membranes, and is converted into negatively charged CS790 under the action of intracellular esterases to be retained, thus enabling highly sensitive, reversible "turn-on" detection of labile Cu+ pools in live cells and mice. CS790AM possesses excellent biocompatibility and selectivity, avoids interference from other metal ions, shows no obvious toxicity, and can be rapidly cleared. CS790AM allows long-term longitudinal monitoring of individual mice, visualizes copper levels in internal organs and isolated livers, and effectively evaluates abnormal copper accumulation in Wilson's disease models (Atp7b-/-) as well as dynamic changes after chelator treatment. CS790AM can be used for research on Wilson's disease and related copper metabolic disorders.
商品は「研究用試薬」です。人や動物の医療用・臨床診断用・食品用の製品ではありません。
研究用途以外に使用した場合、当社は一切の責任を負いかねます。
- CAS 番号: 1416808-87-1
- 分子式: C56H70BrN3O9S3
- 分子量:1105.27
-
保管条件:
Please store the product under the recommended conditions in the Certificate of Analysis.
生物活性
CS790AM, a Cy7-based fluorescent probe, produces a 17-fold fluorescence turn-on response upon binding to Cu+ in cell-free conditions[1].
CS790AM (2 μM; 15 min at 37 °C) reversibly detects fluctuations in labile copper levels in HEK 293T cells, with a significant increase in mean fluorescence intensity in copper-overloaded cells that is reversed by copper chelation[2].
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
CS790AM (0.1 mM; i.p.; single dose) detects aberrantly elevated labile Cu+ levels in Atp7b-/- Wilson disease model mice, producing significantly higher fluorescence signal than in wild-type mice at 30 minutes post-injection, with signal reducible by copper chelation[2].
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
-
Animal Model:SKH-1 (hairless)[2]
-
Dosage:0.1 mM
-
Administration:i.p.; single dose
-
Result:Reversed the ~60% fluorescence increase when co-administered with ATN-224 (HY-16074).
Showed significantly lower fluorescence in mice pretreated with ATN-224 alone compared to mice treated with CS790AM alone.
Confirmed higher fluorescence in copper-pretreated mice via ex vivo liver imaging, with total photon flux values significantly elevated compared to vehicle-pretreated controls.
Showed sustained elevated fluorescence in copper-pretreated mice relative to controls for up to 9 hours post-injection, with signal fully attenuated by 72 hours.
-
Animal Model:C57BL/6 (7-11 weeks old, female; Wilson disease model via Atp7b gene inactivation); wild-type (7-11 weeks old, female)[2]
-
Dosage:0.1 mM
-
Administration:i.p.; single dose
-
Result:Exhibited significantly higher in vivo fluorescence signal in Atp7b-/- mice than wild-type mice at 30 minutes post-injection.
Showed reduced fluorescence in ATN-224-pretreated Atp7b-/- mouse livers compared to vehicle-pretreated controls via ex vivo imaging, correlating with decreased copper levels in serum.
化学情報
-
CAS 番号 1416808-87-1
-
分子量 1105.27
-
分子式 C56H70BrN3O9S3
-
SMILES
O=C(CC[N+]1=C(C(C)(C2=CC=CC=C21)C)/C=C/C(CCC/C3=C\C=C4N(C5=CC=CC=C5C\4(C)C)CCC(OCOC(C)=O)=O)=C3OC6=CC(SCCCSC)=C(C=C6)NCCCSC)OCOC(C)=O.[Br-]
-
別名
Coppersensor 790 acetoxymethyl ester
-
輸送条件
Room temperature in continental US; may vary elsewhere.
-
保管条件
Please store the product under the recommended conditions in the Certificate of Analysis.