BV-1
BV-1 is a fluorescent probe for viscosity detection and imaging in living cells. BV-1 can be used to detect changes in intracellular viscosity and mitochondrial viscosity in living cells. BV-1 responds to environmental viscosity via a molecular rotor mechanism. In a low-viscosity environment, the centrally located unsaturated structure induces a twisted intramolecular charge transfer (TICT) state and promotes non-radiative transitions, resulting in fluorescence quenching; when viscosity increases, molecular rotation is restricted, the TICT state is attenuated, and fluorescence is enhanced with a red shift. BV-1 can be used for real-time monitoring of changes in cytoplasmic viscosity and the viscosity increase during cell apoptosis. Ex/Em = 480/570 nm.
Nos produits utilisent uniquement pour la recherche. Nous ne vendons pas aux patients.
- CAS No.: 2569032-08-0
- Formule: C24H27BF2N2O2
- Masse moléculaire:424.29
-
Stockage:
Please store the product under the recommended conditions in the Certificate of Analysis.
Activité biologique
Description
In Vitro
Guidelines (The following is a recommended experimental protocol for guidance only; please adjust it according to your specific needs)
1. Stock Solution Preparation
1.1 Solvent: Ethanol or DMSO.
1.2 Recommended concentration: 1 × 10-3 M (1 mM).
2. Working Solution Preparation
2.1 Diluent: Cell culture medium.
2.2 Working concentration: 5 μM.
2.3 Notes: Adjust the working solution concentration as required; prepare and use immediately.
3. Staining Procedures
3.1 Applicable to adherent cells:
3.1.1 Sample type: Adherent cells (A549); seed the cells in a culture plate before staining; trypsinization is not required for staining.
3.1.2 Incubation conditions: Incubate at 37°C for 30 min; for A549 cells, incubate in a humidified environment containing 5% CO2; no need for light protection is mentioned in literature.
3.1.3 Washing step: Wash 3 times with phosphate-buffered saline (PBS) after incubation.
4. Control Setup
4.1 Unstained control: Used to adjust instrument voltage and eliminate autofluorescence of cells.
4.2 Blank control: Only add BV-1 without drug treatment, used to exclude fluorescence changes caused by the dye itself.
5. Detection and Analysis
5.1 Instrument type: Laser confocal microscope, confocal fluorescence microscope.
5.2 Excitation/emission wavelength: Ex = 488 nm; Em = 525-650 nm.
5.3 Result analysis:
5.3.1 Changes in fluorescence intensity: The higher the environmental viscosity, the stronger the fluorescence intensity; a time-dependent fluorescence enhancement can be observed during the increase of cellular viscosity.
5.3.2 Fluorescence localization: The fluorescence of BV-1 localizes to mitochondria, showing red fluorescence; the fluorescence is weak at low viscosity, while it increases significantly with an emission redshift at high viscosity.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
Chemical Information
-
CAS No. 2569032-08-0
-
Masse moléculaire 424.29
-
Formule C24H27BF2N2O2
-
SMILES
CCC1=C(C)N2[B-](F)(F)[N+]3=C(C)C(C)=C(C)C3=C(/C=C/C4=CC(O)=CC=C4O)C2=C1C
-
Livraison
Room temperature in continental US; may vary elsewhere.
-
Stockage
Please store the product under the recommended conditions in the Certificate of Analysis.
Pureté et documentation
Références
Calculators
Concentration (start) × Volume (start) = Concentration (final) × Volume (final)