BV-1
BV-1 is a fluorescent probe for viscosity detection and imaging in living cells. BV-1 can be used to detect changes in intracellular viscosity and mitochondrial viscosity in living cells. BV-1 responds to environmental viscosity via a molecular rotor mechanism. In a low-viscosity environment, the centrally located unsaturated structure induces a twisted intramolecular charge transfer (TICT) state and promotes non-radiative transitions, resulting in fluorescence quenching; when viscosity increases, molecular rotation is restricted, the TICT state is attenuated, and fluorescence is enhanced with a red shift. BV-1 can be used for real-time monitoring of changes in cytoplasmic viscosity and the viscosity increase during cell apoptosis. Ex/Em = 480/570 nm.
商品は「研究用試薬」です。人や動物の医療用・臨床診断用・食品用の製品ではありません。
研究用途以外に使用した場合、当社は一切の責任を負いかねます。
- CAS 番号: 2569032-08-0
- 分子式: C24H27BF2N2O2
- 分子量:424.29
-
保管条件:
Please store the product under the recommended conditions in the Certificate of Analysis.
生物活性
製品説明
体外実験
1. Stock Solution Preparation
1.1 Solvent: Ethanol or DMSO.
1.2 Recommended concentration: 1 × 10-3 M (1 mM).
2. Working Solution Preparation
2.1 Diluent: Cell culture medium.
2.2 Working concentration: 5 μM.
2.3 Notes: Adjust the working solution concentration as required; prepare and use immediately.
3. Staining Procedures
3.1 Applicable to adherent cells:
3.1.1 Sample type: Adherent cells (A549); seed the cells in a culture plate before staining; trypsinization is not required for staining.
3.1.2 Incubation conditions: Incubate at 37°C for 30 min; for A549 cells, incubate in a humidified environment containing 5% CO2; no need for light protection is mentioned in literature.
3.1.3 Washing step: Wash 3 times with phosphate-buffered saline (PBS) after incubation.
4. Control Setup
4.1 Unstained control: Used to adjust instrument voltage and eliminate autofluorescence of cells.
4.2 Blank control: Only add BV-1 without drug treatment, used to exclude fluorescence changes caused by the dye itself.
5. Detection and Analysis
5.1 Instrument type: Laser confocal microscope, confocal fluorescence microscope.
5.2 Excitation/emission wavelength: Ex = 488 nm; Em = 525-650 nm.
5.3 Result analysis:
5.3.1 Changes in fluorescence intensity: The higher the environmental viscosity, the stronger the fluorescence intensity; a time-dependent fluorescence enhancement can be observed during the increase of cellular viscosity.
5.3.2 Fluorescence localization: The fluorescence of BV-1 localizes to mitochondria, showing red fluorescence; the fluorescence is weak at low viscosity, while it increases significantly with an emission redshift at high viscosity.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
化学情報
-
CAS 番号 2569032-08-0
-
分子量 424.29
-
分子式 C24H27BF2N2O2
-
SMILES
CCC1=C(C)N2[B-](F)(F)[N+]3=C(C)C(C)=C(C)C3=C(/C=C/C4=CC(O)=CC=C4O)C2=C1C
-
輸送条件
Room temperature in continental US; may vary elsewhere.
-
保管条件
Please store the product under the recommended conditions in the Certificate of Analysis.
純度とドキュメンテーション
参考文献
Calculators
濃度 (開始) × 体積 (開始) = 濃度 (終了) × 体積 (終了)