BCECF Acetoxymethyl ester
Based on 1 Customer Validation
BCECF Acetoxymethyl ester is a cell membrane permeable compound widely-used as a fluorescent indicator for intracellular pH. BCECF Acetoxymethyl ester could diffuse through the cell membrane and intracellular esterase cleave the ester bond releasing BCECF (HY-101882). BCECF allows measurements in the physiological pH range 6.0-8.0. Excitation ratio: 490/440 nm; Emission intensity: 535 nm.
For research use only. We do not sell to patients.
- Purity: 95%
- Formula: C42H40O21
- Molecular Weight:880.76
-
Storage:
Solution, -20°C, protect from light, 2 years
Biological Activity
Guide (The following is our recommended protocol. This protocol is only a guide and should be modified according to your specific needs).
The pH-sensitive fluorescent dyes to measure cytosolic pH[2][3].
1.Prepare a 5 mM stock solution of BCECF Acetoxymethyl ester in DMSO.
2.Prepare a 3-5 μM BCECF Acetoxymethyl ester dye-loading solution in NMG buffer (10?mM HEPES, 60?mM KCl, 3?mM MgCl2, pH 6.8) or PBS.
3. Add BCECF Acetoxymethyl ester dye-loading solution (3-5 μM) into the cell plate for 30-60 min at 37°C in the dark.
4. Cells are washed three times with PBS.
5. Run the pH assay by monitoring the fluorescence at Ex/Em = 490/535 nm or 440/535 nm for ratio measurements.
Standard Curve Determination:
1. pH calibration buffer: 130?mM KCl, 1?mM MgCl2, 15?mM HEPES, 15?mM MES (HY-D0858), 10?μM Nigericin sodium salt (HY-100381), and 10?μM Valinomycin (HY-N6693) (to balance the intracellular and extracellular pH). Adjust to pH 6.5, 7.0, 7.5, 8.0, and 8.5 with NaOH or HCl.
2. Incubate the stained cells in calibration buffer at pH 6.5, 7.0, 7.5, 8.0, and 8.5 for 10 minutes, respectively.
3. Measure the F490/F440 ratio at each pH value. Plot a standard curve with pH as the horizontal axis and fluorescence ratio as the vertical axis (this curve should be sigmoidal and can be fitted using the Henderson-Hasselbalch equation).
4. Substitute the fluorescence ratio (R) of the unknown sample measured in the experiment into the standard curve to determine the corresponding pH value.
MedChemExpress (MCE) has not independently confirmed the accuracy of these methods. They are for reference only.
Chemical Information
-
Appearance Liquid
-
Molecular Weight 880.76
-
Formula C42H40O21
-
Color Brown to reddish brown
-
SMILES
O=C(OCOC(C)=O)CCC1=CC(C23OC(C4=C2C=C(C(OCOC(C)=O)=O)C=C4)=O)=C(OC5=C3C=C(CCC(OCOC(C)=O)=O)C(OCOC(C)=O)=C5)C=C1OCOC(C)=O.O=C(OCOC(C)=O)CCC6=CC(C78OC(C9=C7C=CC(C(OCOC(C)=O)=O)=C9)=O)=C(OC%10=C8C=C(CCC(OCOC(C)=O)=O)C(OCOC(C)=O)=C%10)C=C6OCOC(C)=O
-
Shipping
Room temperature in continental US; may vary elsewhere.
-
Storage
Solution, -20°C, protect from light, 2 years
Purity & Documentation
-
Data Sheet (285 KB)
-
SDS (252 KB)
- English - EN (252 KB)
- Français - FR (252 KB)
- Deutsch - DE (252 KB)
- Norwegian - NO (252 KB)
- Español - ES (252 KB)
- Swedish - SV (252 KB)
- Italian - IT (252 KB)
- Korean - KR (252 KB)
- Portuguese - PT (252 KB)
-
Handling Instructions (2659 KB)
References
[1]. Ozkan P, et al. A rapid method for measuring intracellular pH using BCECF-AM. Biochim Biophys Acta. 2002 Aug 15;1572(1):143-8. [Content Brief]
[2]. Chen F, et al. CYP51A1 drives resistance to pH-dependent cell death in pancreatic cancer. Nat Commun. 2025 Mar 7;16(1):2278. [Content Brief]
[3]. Pang X, et al. Weak acids produced during anaerobic respiration suppress both photosynthesis and aerobic respiration. Nat Commun. 2023 Jul 14;14(1):4207. [Content Brief]
Calculators
Concentration (start) × Volume (start) = Concentration (final) × Volume (final)